Section 7 - Maintenance - 61Microrouter CNC Machine User's Manual
7: Laminate Trimmer Maintenance
Daily.
Unplug the power lead from the laminate trimmer motor, at the
junction on the upper slideframe box section. Open the clamp on
the machine head, using a 5mm allen key, then remove the laminate
trimmer to a suitable workbench for cleaning and inspection (see
section 5 - Preparing Tooling Hardware, for further details on removing
and replacing the laminate trimmer).
Carefully remove any dust and debris from all air passages, using a
vacuum cleaner. DO NOT use compressed air for this purpose.
Pay particular attention to any dust or debris that may have been
drawn into the motor. Remove any buildup of grime resulting from
working with green or sappy timber. This practice with extend the
life of your motor and its brushes.
Failure to Start.
Should the motor fail to start, check that the prongs on the mains
power cord plug are making good contact inside the outlet. Check for
any blown fuses, replace them and recitify the cause.
Lubrication.
The laminate trimmer motor has been lubricated with a sufficient
amount of high grade lubricant for the life of the unit under normal
operating conditions. No further lubrication is necessary.
Brush Inspection.
At approximately 100 hours of use, Denford recommends you take
or send your motor to your nearest authorised laminate trimmer
service station or Denford agent to be thoroughly cleaned and
inspected; worn parts replaced, where necessary; relubricated with
fresh lubricant, if required; reassembled with new brushes; and
performance tested.
Any loss of power before the above maintenance check may
indicate the need for immediate servicing of your laminate trimmer.
Do not continue to operate the laminate trimmer under these
conditions.
Caution.
Wear safety glasses
and a suitable
respiratory mask whilst
cleaning.
If the cutting tool has
been recently used, it
may still be HOT.
Safety First !
-